Erector/Dismantle Checklist
| Erector/Dismantle Checklist Example: | ||
| Instructions: Use the checklist below to inspect scaffold components prior to initiating erection / dismantling. Note – This checklist applies to supported scaffolds. Choose an answer for each statement with: Yes – No – N/A | ||
| Inspectors Name: Date: | Yes | No |
| Scaffold has been designed by a Qualified Person (QP) | ||
| Erectors and dismantlers have been trained by a Competent Person (CP) | ||
| Scaffold is erected, moved, dismantled or altered under the supervision of a CP | ||
| A CP has determined the means of access / egress to the scaffold | ||
| A CP determines feasible safe access at each stage of erection / dismantling | ||
| Hook-on or attachable ladders and/or stair cases are installed as soon as possible | ||
| Bottom step of access ladders is no more than 24” above or below scaffold support level | ||
| Cross bracing is not used as a means of access / egress to the platform | ||
| Erectors / dismantlers used fall protection systems when feasible (determined by CP) | ||
| Scaffold is built from the bottom up and dismantled from the top down | ||
| Poles, legs, posts, frames and uprights bear on base plates | ||
| Scaffold is secured to the structure during erection / dismantling | ||
| Ties to the structure are installed as soon as the scaffold is completed in each tie-in area | ||
| Ties are removed only as dismantling activities progress downward | ||
| Scaffolds which exceed the 4-to-1 base / height ratio are prevented from tipping | ||
| Scaffold components from different manufacturers are not used unless they fit together easily and | ||
| do not affect the scaffold’s integrity ( QP approval required) | ||
| Damaged scaffold components are removed from service and replaced until repaired | ||
| Scaffold is free from corrosion, bends, kinks, excessive dirt / mud / concrete | ||
| Platforms are secure so they can’t slip from supports | ||
| The end of each abutted plank on a long platform rests on a separate support | ||
| Structural members are not removed below the level being dismantled |